Fluke 355 True-rms 2000A Clamp Meter high-current !!NEW!! F355CN

$ 277.2

Model: 355 Brand: Fluke

Description

Fluke 355 True-rms 2000A Clamp Meter high-current !!NEW!! F355CN. The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors. Crest Factor (50/60 Hz) Range 40 A / 400 A / 2000 A; 1400 ac rms. Crest Factor 2 @ 33 A, 2.4 @ 27 A. (600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.). Versatile and rugged tools for applications with high currents Confidently take reliable readings with the True-rms, Fluke 355 digital clamp meter the tool of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements. Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors CAT IV 600 V, CAT III 1000 V rating for added user protection In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows the user to perform multiple tests with only one tool Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter. Accurately measure frequency up to 1 kHz for optimum troubleshooting Quickly analyze readings using the MIN, MAX, and AVG functions A large backlit display allows for easy visibility in low-lit areas Use the display hold feature to capture readings even when the display cannot be viewed Use the low-pass filter to smooth out noisy loads and stabilize readings Current measurement dc and ac 10 Hz to 100 Hz Range 40 A / 400 A / 2000 A; 1400 ac rms Resolution 10 mA / 100 mA / 1 A Accuracy A: 1.5 % rdg + 15 digitsA: 1.5 % rdg + 5 digits Trigger Level for Inrush 0.50 A / 5.0 A / 5 A Trigger Level for Hz Filter OFF 2.50 A / 2.5 A / 8 A Trigger Level for Hz Filter ON 0.50 A / 2.5 A / 8 A Crest Factor (50/60 Hz) Range 40 A / 400 A / 2000 A; 1400 ac rms Crest Factor* 2 @ 33 A, 2.4 @ 27 A2 @ 330 A, 2.4 @ 270 A2 @ 1000 A, 2.4 @ 833 A Current measurement ac 100.1 Hz to 1 kHz Range 40 A / 400 A / 2000 A; 1400 ac rms Resolution 10 mA / 100 mA / 1 A Accuracy 10 A : 3.5 % rdg + 15 digits10 A : 3.5 % rdg + 5 digits Trigger Level for Inrush 0.50 A / 5.0 A / 5 A Trigger Level for Hz Filter OFF 2.50 A / 2.5 A / 8 A Trigger Level for Hz Filter ON 0.50 A / 2.5 A / 8 A Voltage measurement dc and ac 10 Hz to 100 Hz (600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.) Range 4 V / 40 V / 400 V / 600 V ac rms / 1000 V dc Resolution 1 mV / 10 mV / 100 mV / 1 V Accuracy 1 % rdg + 10 digits1 % rdg + 5 digits Trigger Level for Hz Filter OFF 0.25 V / 6 V Trigger Level for Hz Filter ON 0.25 V / 6 V Voltage measurement ac 100.1 Hz to 1 kHz (600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.) Range 4 V / 40 V / 400 V / 600 V ac rms Resolution 1 mV / 10 mV / 100 mV / 1 V Accuracy 3 % rdg + 10 digits3 % rdg + 5 digits Trigger Level for Hz Filter OFF 0.050 V / 0.25 V / 6 V Trigger Level for Hz Filter ON 0.050 V / 0.25 V / 6 V Ohms measurement Range 4 kΩ / 40 kΩ / 400 kΩ Resolution 0.1 Ω / 1 Ω / 10 Ω / 100 Ω Accuracy 1.5 % + 5 digits Continuity beeper On at ≤ 30 ΩOff at ≥ 100 Ω Frequency measurement Measurement range 5.0 Hz to 1 kHz Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) Accuracy – 5.0 Hz to 100 Hz 0.2 % + 2 counts Accuracy – 100.1 Hz to 1 kHz 0.5 % + 5 counts Trigger level Refer to current and voltage tables *Add 2 % to error spec for CF > 2 General Specifications Batteries Six 1.5 V AA NEDA 15 A or IEC LR6 Battery life (with typical usage, backlight off) 100 hours Test leads Rated to 1000 V Weight .814 kg (1.8 lb) Jaw size 58 mm (2.28 in) Dimensions (LxWxD) 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in) Safety rating IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III Environmental Specifications Operating temperature 32 °F to + 122 °F (0 °C to +50 °C) Storage temperature -4 °F to 140 °F (-20 °C to +60 °C) Operating humidity 0 to 95 % (non-condensing) Operating altitude 2000 m Storage altitude 10,000 m IP rating 42 (indoor use only) Drop test requirements 1 m EMI, RFI, EMC FCC part 15, IEC/EN 61326-1:1997 class BIEC/EN 61326:1997 3V/m, performance criteria B, EN61325 Temperature coefficients Current 0.1 % of reading per °C outside 22 °C to 24 °C Voltage 0.1 % of reading per °C outside 22 °C to 24 °C Notice: The standard package don't include batteries.Because,the international air shipping forbid to ship liquid,powder and batteries,we can not put them in the package box.Hope you can understand buy them in your local store or supermarket.Thanks for your support! Shipping: We will ship all items within 1-3 working days upon receipt of payment,our goal is: ship it as fast as we can. Standard Shipping: To USA,UK and Australia by ePacket,need 7-12 working days. Expedited/Standard Int'l Shipping by Fedex,DHL,TNT and EMS courier: To USA,need 3-6 business days,To other countries,need 4-8 business days normally.But sometimes int'l delivery is highly depended on the courier company and local customs/duties. Import duties and taxes are not included in the item price or shipping charges.These charges are the buyer responsibility. Warranty&Reture Policy: We encourage all customers to communicate with us through eBay messages. If you have any questions or comments whatsoever regarding our products or listing, we are waiting to hear from you A 1 year warranty is offered for this product.If the product malfunctioned under proper usage per instructions manual within the warranty period, please contact us to obtain shipping instructions and send it back at your shipping costs. 30 days evaluation and investigation takes placed after receiving your return item.A brand new replacement unit will be sent to you at our shipping costs if it meets our warranty requirements. On Feb-05-20 at 15:54:59 PST, seller added the following information: On Oct 10, 2025 at 03:35:39 PDT, seller added the following information: On May 8, 2026 at 05:24:29 PDT, seller added the following information: